# MGA0800 air conditioning module for outdoor totems

> Overview of the MGA0800 air conditioning module used in outdoor digital totems: working principle, technical specifications and compliance standards.

The **MGA0800** air conditioning module cools the inside of outdoor digital totems and protects temperature-sensitive electronics. This page covers the working principle, technical specifications and standards the module complies with.

<Note>
  All operations on this product must be performed by qualified engineers or technicians. Read the manual carefully before use and follow its instructions and notes.
</Note>

## Product introduction

The air conditioner is a refrigeration product developed specifically for cabinets. It suits locations where the heat generated inside the cabinet is very high, the internal electronics are sensitive to ambient temperature, and the inside must be fully isolated from the outside. The product has multiple functions, high reliability, and starts working right after power-up with no complex configuration.

### Working principle

The module has two separate air paths:

* **Internal path:** the fan draws hot air from the top of the cabinet, passes it through the evaporator fins for heat exchange, and sends the cooled air out of the bottom of the unit. The cabinet air circulates continuously and the temperature drops.
* **External path:** the fan draws cooler outside air from the bottom and discharges hot air from the top after heat exchange.

| Airflow | Direction |
| - | - |
| Warm air inlet (inside cabinet) | Top, inside the cabinet |
| Cool air outlet (inside cabinet) | Bottom, inside the cabinet |
| External path | Inlet and outlet on the sides, outside the cabinet |

## Technical specifications

| Category | Parameter | Value |
| - | - | - |
| Dimensions and mounting | Body dimensions (W × H × D) | 600 × 450 × 185 mm |
| | Dimensions with flange (W × H × D) | 638 × 450 × 185 mm |
| | Weight | 19.5 kg |
| | Mounting method | Door mounted |
| | Installation environment | Outdoor |
| Environment and protection | Operating ambient temperature | -40 °C to +55 °C |
| | Noise | 54 dB(A) |
| | Life expectancy | > 10 years |
| | IP rating | IP55 |
| | Refrigerant | R134a |
| | RoHS certification | Yes |
| Performance | Input voltage | 220 V AC ±15 %, 50 Hz |
| | Cooling capacity (L35/L35) | 800 W |
| | Rated cooling input power (L35/L35) | 385 W |
| | Rated cooling current (L35/L35) | 1.8 A |
| | Heating capacity (optional) | 500 W |
| | Internal circulation airflow | 240 m³/h |

<Warning>
  Do not start the module if the system contains no refrigerant. Running the compressor without refrigerant damages it permanently and voids the warranty. See also [Outdoor equipment](/en/operare/echipamente-outdoor).
</Warning>

## Standards

| No. | Standard | Name |
| - | - | - |
| 01 | GB 4208 | Enclosure protection class |
| 02 | GB/T 4857.5, 9, 10, 11, 16 | Packaging: basic tests for transport packages |
| 03 | GB/T 2423.1, 2, 3, 8, 10, 17, 38 | Environmental tests for electrical and electronic products |
| 04 | GB9254-1998 | IT equipment: radio disturbance characteristics, limits and methods of measurement |
| 05 | GJB150-86 | Environmental test methods for military equipment |
| 06 | GB/T17626.8 | EMC: power frequency magnetic field immunity test |
| 07 | YD/T 2768-2014 | Temperature control devices for outdoor communication rooms, part 1: embedded devices |
| 08 | EN 55022:2006+A1:2007 | Conducted emission and radiation test |
| 09 | EN 61000-3-2:2006+A2:2009 | Harmonic current |
| 10 | EN 61000-3-3:2008 | Voltage fluctuation and flicker |
| 11 | EN 61000-4-2:2009 | ESD |
| 12 | EN 61000-4-3:2006 | Radiated disturbance immunity test |
| 13 | EN 61000-4-4:2004 | Electrical fast transient burst |
| 14 | EN 61000-4-5:2006 | Surge |
| 15 | EN 61000-4-6:2009 | Conducted disturbance immunity test |
| 16 | EN 61000-4-11:2004 | Voltage dips and short interruptions |

## In this manual

<CardGroup cols={2}>
  <Card title="Installation" icon="screwdriver-wrench" href="/en/aer-conditionat/instalare">
    Unpacking, mechanical mounting and electrical connections.
  </Card>

  <Card title="Operation" icon="snowflake" href="/en/aer-conditionat/functionare">
    Cooling, heating, monitoring, display and parameters.
  </Card>

  <Card title="Troubleshooting and maintenance" icon="wrench" href="/en/aer-conditionat/depanare-mentenanta">
    Alarms, faults, fixes and maintenance schedule.
  </Card>

  <Card title="Contact" icon="headset" href="/en/suport/contact">
    Totem Digital Romania technical support.
  </Card>
</CardGroup>


## Related topics

- [Install the MGA0800 air conditioning module on a totem](/en/aer-conditionat/instalare.md)
- [MGA0800 air conditioner operation, display and parameters](/en/aer-conditionat/functionare.md)
- [Air conditioning module alarms, troubleshooting and upkeep](/en/aer-conditionat/depanare-mentenanta.md)
- [Installing and Operating Outdoor Digital Totem Kiosks](/en/operare/echipamente-outdoor.md)
- [Operating Environment Requirements for Digital Totems](/en/instalare/mediu-operare.md)


This documentation is built and hosted on [Mintlify](https://mintlify.com), a developer documentation platform.